Everything You Need To Know About Fire-rated Access Doors




There are certain buildings or remodeling jobs that might require a fire-rated door. These are often installed in office buildings, public buildings, and dormitories, and most of all, in exit stairwells. Some residences may also require a fire-rated door but this is less common than commercial buildings. If you’re having doubts about whether you should install fire-rated access doors, then you should probably finish this article until the end because we will tell you everything you need to know about fire-rated access doors.

What is a fire-rated access door?

A fire-rated access door is a very heavy door made of materials such as gypsum or metal and its primary purpose is to hold back smoke and contain the fire. It is called fire-rated because it means that when the door is installed properly, it is not supposed to combust during a certain period of time in an average fire.

Each fire-rated door must be installed following certain specifications and also requires specific door hardware and sealants to maintain the fire-rating. Whether working on new construction or renovation of an older property, it’s important to get access doors with the proper fire-rating for code compliance safety. The time ratings for fire-rated access doors vary and some standard ratings include 20-90 minute doors. Small companies or government agencies may determine fire ratings depending upon the area.

Why does fire-rating matter?
Access doors that are fire-rated are designed to withstand the heat from a fire for a certain amount of time before actually failing. Fire-resistance rating is the duration for which a passive fire protection system withstands a fire-resistance test. That gives time to either control and put out the fire or help the people get out of the building.

Access doors are usually used to conceal gas lines, HVAC, electrical wirings, and plumbing or anything that might be flammable. To protect these systems, access doors need to be fire-rated. Different ratings will indicate how well a door or assembly can withstand fire and they are dependent on factors such as the intensity of the fire and how the access door is mounted. Fire-rated access doors come both in outward and upward swinging and you can also determine if you want them to have an automatic or manual latch release.

Lastly, fire-rated access doors are also essential in making any building LEED-certified. This kind of certification is both economically and environmentally-friendly, as well as lowers energy costs.

What are the types of fire-rated access doors?
Fire-rated access doors are classified according to their fire-rating. Access doors can provide 20 minutes, 45 minutes, or even up to 180 minutes of protection. There are also doors that are called “temperature rise doors”. These doors try to limit heat transfer from one side of the door to the other door. They help prevent injury and provide an easier escape in fire situations. However, because of the advent of automated sprinkler systems changed this and these doors are no longer necessary in commercial installations if the building has a sprinkler system with complete interior floor coverage.
Mounting Considerations

Another factor that affects fire-rating is how an access door is mounted. For example, a fire-rated access door that is good for 60 minutes mounted on flammable wooden studs could be good for three hours on a non-flammable enclosure. It takes more time and more cost but provides better safety and security in case of a severe fire event.

Latching Mechanisms For Fire Rated Access Doors
An active latch bold that can withstand the pressure that fire can cause is also required for fire-rated access doors and other assemblies. Access doors can also have either automatic or manual latching mechanisms. Some businesses have a mix of doors with both automatic and manual latches.

Ensuring that your livelihood is protected from fire is not a joke. That’s why it is important to understand fire-rating, fire-rated access doors, and all other passive fire-resistance mechanisms.

Are you looking for fire-rated access doors with different fire ratings? Visit https://www.accessdoorsandpanels.com/fire-rated-access-doors/ to know more about our fire-rated access doors.

Comments

Popular posts from this blog

Important Access Door Construction Requirements To Follow

Installing the necessary components and systems is essential to creating a perfect construction. Electrical, plumbing, fire prevention, ventilation, and HVAC are just a few examples of building systems and components. On the other hand, contractors can only operate if they provide adequate protection from various factors.     Installing the best access doors in a building is one approach to keep those components safe. Access panels are an essential part of the installation process for air ducts, which must meet several safety and maintenance requirements. All critical considerations are finding the right access panels, putting them in the right places, and ensuring they comply with local building requirements.       How Bu ildings U se D ifferent K inds of A ccess doors        Security Access Doors.  Facilities that maintain the highest level of security can benefit significantly from installing security access doors. Most of the time, these panels are made of sturdy materials and hav

Several Ways to Save Electricity in a Commercial Building

It makes sense for building owners to look for new ways to make their buildings more energy-efficient. Something as simple as reducing electricity consumption can make a big difference in terms of costs and impact on the environment. Some building components like the HVAC system constantly runs to maintain acceptable air quality and flow, but there are many ways you can still lower electricity consumption. Access Doors and Panels is happy to provide some helpful suggestions: Method #1: Unplug All Unused Appliances The first step to achieving lower electricity bills is to unplug appliances when not in use. Building owners can also suggest this to tenants; educating them about phantom power is an excellent place to start (Phantom power is a term used to describe energy consumption by unused appliances left plugged in).  Ask your building tenants to unplug unused appliances, gadgets, or machines before leaving the building. You can also put up signs or reminders on walls to help them rem

The Complete Guide To HVAC Installation

As an establishment owner, you would always want to invest in something that will benefit your clients and workers. One good investment for your commercial building is by installing an efficient HVAC system. Your HVAC is one of the most important mechanical systems in your establishments. This system provides your occupants great comfort and ambiance that immensely affects their productivity and way of living. Installing your HVAC system may seem like a job for professionals, but with the right amount of research and practice, you might as well be able to do it on your own.    The Best Time To Install Your HVAC System   The best time to install an HVAC system is in the Springtime due to the simple fact that it won't be needed for the year's highest or lowest temperatures while offline. Although installing an HVAC can be completed in any season, having a moderate climate will give you more convenience.    Safety Procedures   If you have doubts about proceeding with this project,